381 G1/2" / G3/4" G1/2" / G3/4" G1/2" / G3/4" A P R A P R AC-XN Safety control unit ■ Pneumatic diagram ■ Electric diagram Pneumatic diagram AC-XN Electric connection AC-XN Electric diagram AC-XN chuck pneumatic supply 10 bar airf low sensor valve jaws moving inwards valve jaws moving outwards pressure switch 1-10 bar valve 2 MV Y2 AC-XN internal external Foot switch clamp unclamp M-Codes signals spindle clamp unclamp stop low pressure in chuck chuck completely open chuck completely closed clamped (air flow) clamped (air flow) Pneumatic modul only one power supply !! clamp unclamp clamp unclamp low pressure in chuck chuck completely open chuck completely closed foot switch Airflow sensor System pressure jaws move out jaws move in unclamped (air flow) unclamped (air flow) completely open (proximity switch) failure messages completely closed (proximity switch) completely closed (proximity switch) failure completely open (proximity switch) valve 1 MV Y1 spindle stop 0= spindle rotation M-Codes signals messages 9 BIS Specials Website: www.bisspecials.com Email: info@bisspecials.com Tel: (0031) 0313 482566 Website: www.bisspecials.com Email: info@bisspecials.com Tel: (0031) 0313 482566