Rego-Fix BIS Specials

Collet groove Eccentric ring Mark on bottom Mark on bottom Assembling Disassembling 107 REGO-FIX AG ER System / Product catalog Assembly instructions Proper assembly protects your runout TIR High standards for all Hi-Q ® / ER clamping nuts Hi-Q ®  / ER clamping nuts with corrosion-resistant surface are standard on all REGO-FIX ER colletholders. Assembling collet Insert groove of the collet into eccentric ring of the clamping nut at the mark on the bottom of the nut. Push collet in the direction of the arrow until it clicks in. Insert tool. Screw nut with collet onto toolholder. Removing collet After the nut is unscrewed from the toolholder, press on the face of the collet while simultaneously pushing sideways on the back of the collet opposite the mark until it disengages from the clamping nut. Correct assembling Improper assembly can permanently damage the runout TIR of the collet and may result in the destruction of the clamping nut. Only mount nuts with correctly inserted collets. Never place the collet into the holder without first assembling into the nut. We recommend the use of original REGO-FIX torque wrenches to prevent any damages to the ER nut. For the recommended tightening torque for ER clamping nuts, please refer to page 157. Expert advice Please only set back-up screw to the tool shank after clamping the tool. Disregarding this will result in bad run out and reduced clamping force. 3.0 ER clamping nuts, reCool ® , disks www.bisspecials.com Website: www.bisspecials.com Tel: (+31) 0313 482566 Email: info@bisspecials.com Website: www.bisspecials.com Tel: (+31) 0313 482566 Email: info@bisspecials.com